Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 770
Filtrar
1.
Transfusion ; 64(4): 665-673, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38456520

RESUMO

BACKGROUND: Microbial screening of platelet concentrates (PC) with automated culture methods is widely implemented to reduce septic transfusion reactions. Herein, detection of bacterial contamination in PC was compared between units prepared in plasma and a mix of plasma and platelet additive solution (PAS) and between the BACT/ALERT 3D and next generation BACT/ALERT VIRTUO systems. STUDY DESIGN/METHODS: Double apheresis units were split into single units, diluted in either PAS (PAS-PC) or plasma (plasma-PC), and tested for in vitro quality and sterility prior to spiking with ~30 CFU/unit of Staphylococcus epidermidis, Staphylococcus aureus, Serratia marcescens, and Klebsiella pneumoniae or ~10 CFU/mL of Cutibacterium acnes. Spiked PC were sampled for BACT/ALERT testing (36 and 48 h post-spiking) and colony counts (24, 36, and 48 h post-spiking). Times to detection (TtoD) and bacterial loads were compared between PC products and BACT/ALERT systems (N = 3). RESULTS: Bacterial growth was similar in plasma-PC and PAS-PC. No significant differences in TtoD were observed between plasma-PC and PAS-PC at the 36-h sampling time except for S. epidermidis which grew faster in plasma-PC and C. acnes which was detected earlier in PAS-PC (p < .05). Detection of facultative bacteria was 1.3-2.2 h sooner in VIRTUO compared with 3D (p < .05) while TtoD for C. acnes was not significantly different between the two systems. DISCUSSION: Comparable bacterial detection was observed in plasma-PC and PAS-PC with PC sampling performed at 36-h post blood collection. PC sampling at ≤36 h could result in faster detection of facultative pathogenic organisms with the VIRTUO system and improved PC safety.


Assuntos
Remoção de Componentes Sanguíneos , Infecções Estafilocócicas , Humanos , Plaquetas/microbiologia , Preservação de Sangue/métodos , Staphylococcus epidermidis , Transfusão de Plaquetas
2.
Vox Sang ; 119(3): 212-218, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38152857

RESUMO

BACKGROUND AND OBJECTIVES: Pathogen reduction (PR) technology may reduce the risk of transfusion-transmitted infections (TTIs), notably transfusion-transmitted bacterial infection (TTBI) associated with platelet concentrates (PCs). PR (amotosalen/UVA treatment) was implemented for all PCs transfused in France in November 2017. No bacterial detection was in place beforehand. The study aimed to assess the impact of PR PC on TTI and TTBI near-miss occurrences. MATERIALS AND METHODS: TTI and TTBI near-miss occurrences were compared before and after 100% PR implementation. The study period ran from 2013 to 2022. Over 300,000 PCs were transfused yearly. RESULTS: No PC-related transmission of human immunodeficiency virus, hepatitis C virus, hepatitis B virus and human T-cell lymphotropic virus was reported throughout the study period. PC-mediated hepatitis E virus and hepatitis A virus infections occurred irrespective of PR implementation. Mean PC-mediated TTBI occurrence before PR-PC implementation was 3/year (SD: 1; n = 15; 1/92,687 PC between 2013 and 2016) with a fatal outcome in two patients. Since PR implementation, one TTBI has been reported (day 4 PC, Bacillus cereus) (1/1,645,295 PC between 2018 and 2022; p < 0.001). Two PR PC quarantined because of a negative swirling test harboured bacteria: a day 6 PC in 2021 (B. cereus and Staphylococcus epidermidis) and a day 7 PC in 2022 (Staphylococcus aureus). Five similar occurrences with untreated PC were reported between 2013 and 2020. CONCLUSION: Transfusion of 100% PR PC resulted in a steep reduction in TTBI occurrence. TTBI may, however, still occur. Pathogen-reduced PC-related TTI involving non-enveloped viruses occurs as well.


Assuntos
Furocumarinas , Reação Transfusional , Humanos , Plaquetas/microbiologia , Reação Transfusional/epidemiologia , Transfusão de Sangue , Bactérias , Transfusão de Plaquetas/efeitos adversos , Raios Ultravioleta
3.
Transfusion ; 64(1): 104-115, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38098310

RESUMO

BACKGROUND AND OBJECTIVES: We evaluated the operational and safety impact of implementing anaerobic culture screening of apheresis and pooled platelets at the American Red Cross on the already established use of the aerobic culture screening of each donation performed no sooner than 24 h following collection. MATERIALS AND METHODS: Platelets were screened for bacterial contamination with the BACT/ALERT 3D® (bioMérieux, Durham, NC) microbial detection testing system. The addition of anaerobic culture to the already existing aerobic culture resulted in sampling an additional 8-10 mL from each donation. RESULTS: Implementation of anaerobic testing resulted in an approximate 3.5-fold increased rate of False Positive BACT/ALERT alarms. There was a modest increase in the rate of True Positive alarms of 1.4-fold with increased detection of Klebsiella and Propionibacterium species, including Cutibacterium acnes. In addition, there was an approximate 3.5-fold increase rate of False Positives and a 13.5-fold increase rate of Indeterminates, the majority (~57%) were due to Cutibacterium acnes. The combined costs and lost revenue associated with adding anaerobic screening increased by ~$1,000,000/year due to testing cost and product discards. CONCLUSION: The addition of anaerobic culture to aerobic culture to the original donation (without the introduction of sampling delay) resulted in a significant increase in the rate of alerts. The 40% increased rate of True Positive alarms may have modestly improved platelet safety. However, there was a disproportionate increase in the rate of False Positive and Indeterminate bacterial culture alarms, which added substantial cost and overall loss of platelet products.


Assuntos
Remoção de Componentes Sanguíneos , Plaquetas , Humanos , Anaerobiose , Plaquetas/microbiologia , Bactérias , Contaminação de Medicamentos , Técnicas Bacteriológicas
5.
Vox Sang ; 118(11): 930-937, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37749879

RESUMO

BACKGROUND AND OBJECTIVES: Platelet concentrates (PCs) contaminated with Cutibacterium acnes are often transfused prior to detection by the BACT/ALERT system. Though C. acnes is implicated in mild transfusion reactions, delayed clinical effects are unknown. This study assessed the ability to enhance C. acnes detection by supplementing culture media with Tween 80 (T80, an oleic acid source) and a commercial nutrient supplement. MATERIALS AND METHODS: Anaerobic culture bottles (BPN) were supplemented with T80 or oleic acid. T80-supplemented BPN bottles were inoculated with four C. acnes isolates (10 or 100 colony-forming units [CFU]/bottle) or other transfusion-relevant bacteria (10 CFU/bottle). Samples of plasma containing SSP+ (platelet additive solution [PAS]) (PAS-plasma) at different concentrations, plasma-PCs and PAS-PCs, spiked with two C. acnes isolates (10 CFU/bottle), were inoculated into T80-supplemented BPN bottles. Furthermore, plasma-PCs were spiked with C. acnes and tested in BPN bottles supplemented with the BD Difco Supplement VX (BDVx). Bottles were incubated in the BACT/ALERT system and times to detection (TtoD) were compared (N = 3). RESULTS: A reduction in TtoD of ≤3.5 days was observed for C. acnes in T80-supplemented BPN, while other species did not show the same effect. However, false positives were observed when T80-supplemented BPN was inoculated with PAS-plasma (except for 70% PAS:30% plasma), plasma-PCs or PAS-PCs. Oleic acid supplementation also resulted in false positives. Interestingly, BDVx-supplemented BPN reduced the TtoD of C. acnes in PCs by ≤1.2 days (p < 0.05), with no false-positive results. CONCLUSION: BDVx supplementation for detection of C. acnes from PCs could result in timely unit retrieval, preventing the transfusion of contaminated products. In clinical settings, T80 supplementation could significantly enhance C. acnes detection from non-blood-derived samples.


Assuntos
Plaquetas , Ácido Oleico , Humanos , Meios de Cultura , Plaquetas/microbiologia , Bactérias , Propionibacterium acnes
6.
Transfusion ; 63(9): 1728-1737, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37453073

RESUMO

BACKGROUND: The updated guidance for improving bacterial detection (BD) of platelets has included the implementation of large-volume delayed sampling (LVDS) with the addition of anaerobic culture bottles (BPNs) and sampling of each platelet split product. METHODS: The frequency of BD was reviewed during this LVDS time period in comparison with pre-LVDS and the Post-Approval Surveillance Study of Platelet Outcomes, Release Tested (PASSPORT) study (when BPNs were last used). RESULTS: There was more than a twofold increase in bottles inoculated per collection during LVDS, with an almost fivefold increase in sample volume collected. During LVDS, the concordance of split products within an initial reactive collection was only 8.7%. There was no difference in LVDS aerobic culture bottle (BPA) true positives (TPs), but there was a significant increase in LVDS false positives (FPs), p < .0001, compared to both PASSPORT and pre-LVDS, respectively. There was an increase in BPN TPs during LVDS (p < .05 compared to PASSPORT), with predominance of Cutibacter acnes (C. acnes), noted exclusively in BPN, and accounting for more than two-fifths of all organisms detected. Time to alarm during LVDS for TPs had two peaks with one due to C. acnes at 96 h compared to 17 h for non-C. acnes. DISCUSSION: The high FP frequency, along with low clinical significance of TPs found in BPNs, has led to the needless discard of inventory, as the utility of BPNs in BD for platelets is yet to be established and may require much larger studies.


Assuntos
Bactérias , Plaquetas , Humanos , Plaquetas/microbiologia
7.
Transfusion ; 63(6): 1224-1229, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37027143

RESUMO

INTRODUCTION: Currently greater than 94% of the US platelet supply is collected by apheresis. A survey to determine the attitudes of members of America's Blood Centers (ABC) toward whole blood derived (WBD) platelets was designed in light of current platelet supply issues. METHODS: An on-line survey was distributed to medical directors of the 47 ABC members. RESULTS: Responses were received from 44/47 (94%) ABC members. There were 15/43 (35%) centers that are currently providing WBD platelets. Seventy percent of the respondents agreed or agreed strongly that WBD and apheresis platelets were clinically equivalent, with approximately 16% indicating that they did not have an opinion on their equivalency and 14% indicating that they were not clinically equivalent. Forty-four percent of respondents felt that their customers would agree or strongly agree that these products are clinically equivalent, while 26% felt that their customers did not know or were neutral on clinical equivalency. The main barrier to WBD platelet implementation was logistic/inventory management issues, followed by bacterial contamination risk mitigation. There were 21/43 (49%) respondents who indicated they are not considering producing WBD platelets to mitigate shortages. Respondents indicated they might begin producing WBD platelets if there was evidence of increasing customer demand, increased reimbursement, inability to supply apheresis platelets, if pathogen reduction became available for WBD platelets, if the platelet shortage worsened. CONCLUSIONS: The majority of blood collectors consider WBD platelets clinically equivalent to apheresis, however wider adoption of WBD platelets is still hindered by challenges with logistics and inventory management.


Assuntos
Remoção de Componentes Sanguíneos , Plaquetas , Humanos , Plaquetas/microbiologia , Transfusão de Plaquetas/métodos , Preservação de Sangue/métodos , Atitude
8.
Transfusion ; 63(4): 711-723, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36802055

RESUMO

BACKGROUND: France converted to universal pathogen reduced (PR; amotosalen/UVA) platelets in 2017 and extended platelet component (PC) shelf-life from 5- to 7-days in 2018 and 2019. Annual national hemovigilance (HV) reports characterized longitudinal PC utilization and safety over 11 years, including several years prior to PR adoption as the national standard of care. METHODS: Data were extracted from published annual HV reports. Apheresis and pooled buffy coat [BC] PC use was compared. Transfusion reactions (TRs) were stratified by type, severity, and causality. Trends were assessed for three periods: Baseline (2010-14; ~7% PR), Period 1 ([P1] 2015-17; 8%-21% PR), and Period 2 ([P2] 2018-20; 100% PR). RESULTS: PC use increased by 19.1% between 2010 and 2020. Pooled BC PC production increased from 38.8% to 68.2% of total PCs. Annual changes in PCs issued averaged 2.4% per year at baseline, -0.02% (P1) and 2.8% (P2). The increase in P2 coincided with a reduction in the target platelet dose and extension to 7-day storage. Allergic reactions, alloimmunization, febrile non-hemolytic TRs, immunologic incompatibility, and ineffective transfusions accounted for >90% of TRs. Overall, TR incidence per 100,000 PCs issued declined from 527.9 (2010) to 345.7 (2020). Severe TR rates declined 34.8% between P1-P2. Forty-six transfusion-transmitted bacterial infections (TTBI) were associated with conventional PCs during baseline and P1. No TTBI were associated with amotosalen/UVA PCs. Infections with Hepatitis E (HEV) a non-enveloped virus resistant to PR, were reported in all periods. DISCUSSION: Longitudinal HV analysis demonstrated stable PC utilization trends with reduced patient risk during conversion to universal 7-day amotosalen/UVA PCs.


Assuntos
Transfusão de Plaquetas , Reação Transfusional , Humanos , Transfusão de Plaquetas/efeitos adversos , Segurança do Sangue , Plaquetas/microbiologia , Transfusão de Sangue , Reação Transfusional/epidemiologia , Reação Transfusional/prevenção & controle , Bactérias
9.
Transfus Clin Biol ; 30(1): 147-165, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36031180

RESUMO

Many patients worldwide receive platelet components (PCs) through the transfusion of diverse types of blood components. PC transfusions are essential for the treatment of central thrombocytopenia of diverse causes, and such treatment is beneficial in patients at risk of severe bleeding. PC transfusions account for almost 10% of all the blood components supplied by blood services, but they are associated with about 3.25 times as many severe reactions (attributable to transfusion) than red blood cell transfusions after stringent in-process leukoreduction to less than 106 residual cells per blood component. PCs are not homogeneous, due to the considerable differences between donors. Furthermore, the modes of PC collection and preparation, the safety precautions taken to limit either the most common (allergic-type reactions and febrile non-hemolytic reactions) or the most severe (bacterial contamination, pulmonary lesions) adverse reactions, and storage and conservation methods can all result in so-called PC "storage lesions". Some storage lesions affect PC quality, with implications for patient outcome. Good transfusion practices should result in higher levels of platelet recovery and efficacy, and lower complication rates. These practices include a matching of tissue ABH antigens whenever possible, and of platelet HLA (and, to a lesser extent, HPA) antigens in immunization situations. This review provides an overview of all the available information relating to platelet transfusion, from donor and donation to bedside transfusion, and considers the impact of the measures applied to increase transfusion efficacy while improving safety and preventing transfusion inefficacy and refractoriness. It also considers alternatives to platelet component (PC) transfusion.


Assuntos
Transfusão de Plaquetas , Trombocitopenia , Humanos , Adulto , Transfusão de Plaquetas/efeitos adversos , Transfusão de Plaquetas/métodos , Plaquetas/microbiologia , Trombocitopenia/terapia , Transfusão de Sangue , Transfusão de Componentes Sanguíneos/efeitos adversos
10.
Transfusion ; 63(1): 182-192, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36371753

RESUMO

BACKGROUND: Non-pathogen reduction platelet bacterial risk control strategies in the US FDA guidance include at least one culture. Almost all of these strategies have a culture hold time of ≥12 h. Studies have reported time to detection (TTD) of bacterial cultures inoculated with bacteria from contaminated platelets, but these data and estimates of risk associated with detection failures have not been synthesized. METHODS: We performed a literature search to identify studies reporting TTD for samples obtained from spiked platelet components. Using extracted data, regression analysis was used to estimate TTD for culture bottles at different inoculum sizes. Detection failures were defined as events in which contaminated components are transfused to a patient. We then used published data on time of transfusion (ToT) to estimate the risk of detection failures in practice. RESULTS: The search identified 1427 studies, of which 16 were included for analysis. TTD data were available for 16 different organisms, including 14 in aerobic cultures and 11 in anaerobic cultures. For inocula of 1 colony forming unit (CFU), the average TTD for aerobic organisms was 19.2 h while it was 24.9 h in anaerobic organisms, but there was substantial overall variation. A hold time of 12 versus 24 h had minimal effect for most organisms. CONCLUSION: TTD variation occurs between bacterial species and within a particular species. Under typical inventory management, the relative contribution of culture detection failures is much smaller than the residual risk from sampling failures. Increasing the hold period beyond 12 h has limited value.


Assuntos
Bactérias , Plaquetas , Humanos , Plaquetas/microbiologia , Fatores de Tempo , Transfusão de Plaquetas
11.
Vox Sang ; 117(11): 1318-1322, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36102149

RESUMO

BACKGROUND AND OBJECTIVES: Platelet concentrates (PCs) contaminated with Staphylococcus aureus can escape detection during PC screening, causing septic transfusion reactions. This study aimed to determine the impact of S. aureus contamination on platelet metabolism and functionality during PC storage. MATERIALS AND METHODS: Targeted metabolomics (N = 3) was performed on non-spiked PCs and PCs inoculated with 10-20 colony-forming units (CFU)/bag of S. aureus. Metabolites were quantified at 0, 48 and 144 h using high-performance mass spectrometry (MS). Additionally, PCs spiked with approximately 20 CFU/bag of S. aureus were sampled every 24 h for up to 144 h to evaluate platelet functionality using flow cytometry (N = 2). RESULTS: Eight metabolites had significantly different levels in spiked PCs (log2 fold-change ≤ or ≥±1) versus non-spiked units at 48 and 144 h. Xanthine, uridine, serine, glutamine and threonine were increased, whereas orotic acid, dihydroorotic acid and aspartic acid were decreased. Flow cytometry showed a significant decrease in expression of GPIIb while P-selectin expression was significantly increased in spiked PCs after 72 h of storage when S. aureus concentration was ≥10E+08 CFU/ml. Additionally, phosphatidylserine exposure was significantly increased after 48 h of PC storage, when S. aureus had reached a concentration of 2E+06. CONCLUSION: Contamination with S. aureus exacerbates platelet storage lesions in contaminated PCs but only when the bacterium has reached clinically significant levels.


Assuntos
Plaquetas , Staphylococcus aureus , Humanos , Plaquetas/microbiologia , Testes de Função Plaquetária , Contaminação de Medicamentos , Bactérias , Transfusão de Plaquetas
12.
Transfusion ; 62(10): 2108-2116, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36052676

RESUMO

BACKGROUND: Bacterial contamination in platelets remain a major public health concern, which prompted the US Food and Drug Administration guidance for bacterial contamination mitigation. Pathogen reduction technology (PRT) is one mitigation strategy that has shown success in Europe over the last decade. Therefore, our center sought to transition from a dual system of bacterial culturing (BacT) and PRT to full PRT. METHODS: A 1 month pilot study was conducted to simulate 100% PRT conditions. Our center also collected baseline data on key platelet production metrics in the 4 months prior to 100% PRT and compared it to the 4 months post-implementation. RESULTS: The pilot study showed no statistical differences in split rate, proportion of low-yield products, or proportion of single, double, and triple collections. The only observed difference was an 11 min increase in the average duration of double collections. Our baseline versus post-implementation monitoring showed no difference in split rate, discard rate, percentage of low-yield units, and average yield of low yield units. Statistical differences were detected in the proportion of single, double, and triple collections, as well as the average yield of full dose products. Roughly 20% of our inventory consisted of low-yield products. DISCUSSION: With suitable mitigation strategies, transitioning to a full PRT inventory may result in higher net margins while not adversely affecting overall platelet production. A pilot study is a good way to project potential effects of switching from a dual BacT and PRT inventory to full PRT, and can be adopted by other centers aiming to make the transition.


Assuntos
Remoção de Componentes Sanguíneos , Plaquetas , Plaquetas/microbiologia , Europa (Continente) , Humanos , Projetos Piloto , Transfusão de Plaquetas , Tecnologia
13.
Transfusion ; 62(10): 2012-2019, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35924914

RESUMO

BACKGROUND: Pathogen reduction technology (PRT) effectively mitigates bacterial contamination in platelets but is more likely to produce low yield units. Although low dose transfusion using conventional platelets has not been associated with increased bleeding, these findings have not been reproduced with PRT-treated platelets. STUDY DESIGN AND METHODS: Platelet transfusions in a tertiary adult hospital were retrospectively reviewed. Comparisons were made between PRT-treated regular (PRT-PR) and low (PRT-PL) yield platelets. Outcomes examined included the number of platelets and RBCs transfused, transfusion-free interval, and corrected count increment (CCI). Subgroup analyses were also performed on hematology-oncology inpatients and outpatients, as well as non-hematology-oncology patients. RESULTS: Platelet utilization per patient remained mostly unchanged (mean 2.9-4.3 units per patient per month) even when the frequency of PRT-PL transfusion increased. Among 1402 patients examined, the number of platelets and RBCs transfused was not significantly different between patients first transfused with PRT-PR versus PRT-PL (mean number of platelet units = 2.8 vs. 3.1, p = 0.38; mean number of RBC units = 4.8 vs. 4.3, p = 0.93). Among 10,257 platelet transfusions examined, the transfusion-free interval (hazard ratio = 1.05, 95% confidence interval 1.00-1.10) and CCI (10.2 vs. 11.0, p = 0.70) were comparable between PRT-PR and PRT-PL units. Similar findings were observed in all subgroups, except for shortened transfusion-free intervals among hematology-oncology inpatients. CONCLUSION: PRT-PR and PRT-PL units may be used in an equivalent manner to maintain an adequate platelet inventory, since there was only a minor difference in time between transfusions.


Assuntos
Neoplasias , Trombocitopenia , Adulto , Plaquetas/microbiologia , Hemorragia , Humanos , Neoplasias/terapia , Transfusão de Plaquetas , Estudos Retrospectivos
14.
Sci Rep ; 12(1): 9151, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35650226

RESUMO

Bacterial contamination of blood products is a major problem in transfusion medicine, in terms of both morbidity and mortality. Platelets (PLTs) are stored at room temperature (under constant agitation) for more than 5 days, and bacteria can thus grow significantly from a low level to high titers. However, conventional methods like blood culture and lateral flow assay have disadvantages such as long detection time, low sensitivity, and the need for a large volume of blood components. We used real-time polymerase chain reaction (PCR) assays with antibiotic-conjugated magnetic nanobeads (MNBs) to detect enriched Gram-positive and -negative bacteria. The MNBs were coated with polyethylene glycol (PEG) to prevent aggregation by blood components. Over 80% of all bacteria were captured by the MNBs, and the levels of detection were 101 colony forming unit [CFU]/mL and 102 CFU/mL for Gram-positive and -negative bacteria, respectively. The detection time is < 3 h using only small volumes of blood components. Thus, compared to conventional methods, real-time PCR using MNBs allows for rapid detection with high sensitivity using only a small volume of blood components.


Assuntos
Bactérias , Contaminação de Medicamentos , Bactérias/genética , Plaquetas/microbiologia , Fenômenos Magnéticos , Plasma
15.
Vox Sang ; 117(8): 983-988, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35412655

RESUMO

BACKGROUND AND OBJECTIVES: Bacterial contamination of platelet components (PCs) poses a safety challenge for transfusion patients. Despite mitigation interventions, the residual risk of transfusion-transmitted bacterial infections remains predominant. PC safety can be improved either by pathogen reduction or by implementation of bacterial detection methods. Detection methodologies include culture methods and rapid detection methods. The current review focuses on currently available rapid detection methods. MATERIALS AND METHODS: We reviewed published manuscripts since 2000 on rapid bacterial detection methods used for PC screening with result determination within 4 h. Methods meeting this criterion included Verax PGDprime, BacTx and nucleic amplification testing. The analytical and diagnostic sensitivity and specificity of these systems were assessed. RESULTS: The analytical sensitivity between the different detection methods ranged between 50 and 100,000 CFU/ml. The sample volume used by these testing systems varies between 0.5 and 1.0 ml of PCs. A delay of at least 48 h before sampling enhances detectability. All rapid detection methods generate results in a timely manner, allowing testing to be performed before transfusion with optimal sensitivity. CONCLUSION: Rapid detection methods improve PC safety regarding bacterial contamination. The assays are optimal for rapidly growing bacteria, which are more likely to cause septic transfusion reactions in patients. Because of the reduced diagnostic sensitivity, the sample collection should be late in shelf-life and ideally just before transfusion. The major benefit of these methods is that the test result can be obtained before releasing PCs for transfusion or to be used in combination with other screening methods applied early during PC storage.


Assuntos
Infecções Bacterianas , Doenças Transmissíveis , Reação Transfusional , Bactérias , Infecções Bacterianas/diagnóstico , Infecções Bacterianas/prevenção & controle , Plaquetas/microbiologia , Transfusão de Sangue , Humanos , Transfusão de Plaquetas/efeitos adversos , Reação Transfusional/etiologia
16.
Vox Sang ; 117(7): 879-886, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35312078

RESUMO

Platelet components are commonly transfused to patients for a variety of indications, including patients with low platelet counts or patients with platelet dysfunction who are bleeding or at high risk of bleeding. Although the risk of pathogen contamination of platelet components has declined significantly over the last 40 years, it remains a concern for the patients, for blood banks and for physicians. Pathogen inactivation (PI) technologies have been developed to mitigate this risk. This review focuses on the residual risks of transfusion-transmitted bacterial infections by platelet transfusion after PI. We describe and assess the relationship between the bacterial load and the timing and capacity of reduction of the different PI technologies, as well as the risks that could represent spore-forming microorganisms and the possible introduction of microorganisms after PI.


Assuntos
Infecções Bacterianas , Trombocitopenia , Reação Transfusional , Bactérias , Infecções Bacterianas/prevenção & controle , Plaquetas/microbiologia , Contaminação de Medicamentos , Humanos , Transfusão de Plaquetas/efeitos adversos
17.
Vox Sang ; 117(5): 647-655, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35178718

RESUMO

In 2014, the bacterial subgroup of the Transfusion-Transmitted Infectious Diseases working party of ISBT published a review on the International Experience of Bacterial Screen Testing of Platelet Components (PCs) with an Automated Microbial Detection System. The purpose of this review, which is focused on publications on or after 2014, is to summarize recent experiences related to bacterial contamination of PCs and the use of an automated culture method to safeguard the blood supply. We first reviewed septic transfusion reactions after PC transfusion as reported in national haemovigilance systems along with a few reports from various countries on bacterial contamination of blood products. Next, we reviewed PC automated culture protocols employed by national blood services in the United Kingdom, Australia, Canada and large blood collection organization and hospital transfusion services in the United States. Then, we acknowledged the limitations of currently available culture methodologies in abating the risks of transfusion-transmitted bacterial infection, through a review of case reports. This review was neither meant to be critical of the literature reviewed nor meant to identify or recommend a best practice. We concluded that significant risk reduction can be achieved by one or a combination of more than one strategy. No one approach is feasible for all institutions worldwide. In selecting strategies, institutions should consider the possible impact on platelet components availability and entertain a risk-based decision-making approach that accounts for operational, logistical and financial factors.


Assuntos
Infecções Bacterianas , Reação Transfusional , Bactérias , Plaquetas/microbiologia , Segurança do Sangue , Transfusão de Sangue , Humanos , Transfusão de Plaquetas , Estados Unidos
18.
Can J Vet Res ; 86(1): 59-64, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34975224

RESUMO

Septic arthritis is considered a medical emergency. Disease following bacterial colonization can lead to significant morbidity and mortality and requires costly treatment. Antimicrobial properties of regenerative therapies, including mesenchymal stromal cells and platelet products, have been researched extensively in human medicine. Although fewer studies have been conducted in veterinary species, they have shown promising results. The purpose of this study was to evaluate bacterial suppression by equine platelet lysate (EPL) and adipose-derived mesenchymal stromal cells (ASCs) in vitro. We hypothesized that both products would significantly inhibit the growth of Staphylococcus aureus and Escherichia coli. Pooled blood from 10 horses was used for production of EPL. Mesenchymal stromal cells were isolated from adipose tissue harvested from the gluteal region of 3 horses. The study evaluated 3 treatment groups: 10 × EPL, 1.6 million ASCs, and a control, using an incomplete unbalanced block design with repeated measurements. Optical density readings and colony-forming units/mL were calculated at 0, 3, 6, 9, 12, 18, and 24 hours. Decreased bacterial growth was seen at multiple time points for the S. aureus-ASC and S. aureus-EPL treatments, supporting our hypothesis. Increased bacterial growth was noticed in the E. coli-EPL group, with no difference in the E. coli-ASC treatment, which opposed our hypothesis. A clear conclusion of antimicrobial effects of EPL and ASCs cannot be made from this in vitro study. Although it appears that ASCs have a significant effect on decreasing the growth of S. aureus, further studies are needed to explore these effects, particularly in Gram-positive bacteria.


L'arthrite septique est considérée comme une urgence médicale. La maladie consécutive à une colonisation bactérienne peut entraîner une morbidité et une mortalité importantes et nécessite un traitement coûteux. Les propriétés antimicrobiennes des thérapies régénératives, y compris les cellules stromales mésenchymateuses et les produits plaquettaires, ont fait l'objet de recherches approfondies en médecine humaine. Bien que moins d'études aient été menées chez les espèces animales, elles ont montré des résultats prometteurs. Le but de cette étude était d'évaluer la suppression bactérienne par le lysat plaquettaire équin (EPL) et les cellules stromales mésenchymateuses adipeuses (ASC) i n vitro. Nous avons émis l'hypothèse que les deux produits inhiberaient de manière significative la croissance de Staphylococcus aureus et d'Escherichia coli. Un pool de sang de 10 chevaux a été utilisé pour la production d'EPL. Des cellules stromales mésenchymateuses ont été isolées à partir de tissu adipeux prélevé dans la région fessière de trois chevaux. L'étude a évalué trois groupes de traitement : 10 × EPL, 1,6 million d'ASC et un témoin, en utilisant un design en blocs non équilibrés incomplets avec des mesures répétées. Les lectures de densité optique et les unités formatrices de colonie/mL ont été calculées à 0, 3, 6, 9, 12, 18 et 24 heures. Une diminution de la croissance bactérienne a été observée à plusieurs moments pour les traitements S. aureus-ASC et S. aureus-EPL, soutenant notre hypothèse. Une croissance bactérienne accrue a été remarquée dans le groupe E. coli-EPL, sans différence dans le traitement E. coli-ASC, ce qui s'opposait à notre hypothèse. Une conclusion claire des effets antimicrobiens de l'EPL et des ASC ne peut pas être tirée de cette étude in vitro. Bien qu'il semble que les ASC aient un effet significatif sur la diminution de la croissance de S. aureus, d'autres études sont nécessaires pour explorer ces effets, en particulier chez les bactéries à Gram positif.(Traduit par Docteur Serge Messier).


Assuntos
Plaquetas , Escherichia coli , Células-Tronco Mesenquimais , Staphylococcus aureus , Tecido Adiposo , Animais , Plaquetas/microbiologia , Escherichia coli/crescimento & desenvolvimento , Cavalos , Células-Tronco Mesenquimais/microbiologia , Staphylococcus aureus/crescimento & desenvolvimento
19.
Transfusion ; 62(2): 439-447, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34994468

RESUMO

BACKGROUND: Cold storage reduces posttransfusion survival of platelets; however, it can improve platelet activation, lower risk of bacterial contamination, and extend shelf-life compared to room temperature (RT) storage. To facilitate large-scale availability, manufacturing process optimization is needed, including understanding the impact of variables on platelet potency and safety. Short time requirements from collection to storage is challenging for large blood centers to complete resuspension and qualify platelets for production. This study evaluated the impact of time from platelet component collection to cold storage on in vitro properties and bacterial growth. STUDY DESIGN AND METHODS: Double-apheresis platelet components were collected from healthy donors, suspended in 65% PAS-III/35% plasma, and split into 2 equal units. One unit was placed into cold storage within 2 h and the other unit after 8 h. Eight matched pairs were evaluated for 12 in vitro parameters. Twenty-four matched pairs were evaluated with 8 bacterial strains tested in triplicate. Samples were tested throughout 21 days of storage. RESULTS: In vitro properties were not different between 2 and 8 h units, and trends throughout storage were similar between arms. Time to cold storage did not significantly impact bacterial growth, with <1 log10 difference at all timepoints between units. DISCUSSION: Our studies showed that extending time to cold storage from 2 to 8 h from collection did not significantly increase the bacterial growth, and the platelet component quality and function is maintained. The ability to extend the time required from collection to storage will improve blood center logistics to feasibly produce CSPs.


Assuntos
Remoção de Componentes Sanguíneos , Plaquetas , Plaquetas/microbiologia , Preservação de Sangue , Criopreservação , Humanos , Plasma , Plaquetoferese
20.
Transfusion ; 62(2): 365-373, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34997763

RESUMO

BACKGROUND: Bloodborne pathogens pose a major safety risk in transfusion medicine. To mitigate the risk of bacterial contamination in platelet units, FDA issues updated guidance materials on various bacterial risk control strategies (BRCS). This analysis presents results of a budget impact model updated to include 5- and 7-day pathogen reduced (PR) and large volumed delayed sampling (LVDS) BRCS. STUDY DESIGN AND METHODS: Model base-case parameter inputs were based on scientific literature, a survey distributed to 27 US hospitals, and transfusion experts' opinion. The outputs include hospital budget and shelf-life impacts for 5- and 7-day LVDS, and 5- and 7-day PR units under three different scenarios: (1) 100% LVDS, (2) 100% PR, and (3) mix of 50% LVDS - and 50% PR. RESULTS: Total annual costs from the hospital perspective were highest for 100% LVDS platelets (US$2.325M) and lowest for 100% PR-7 units (US$2.170M). Net budget impact after offsetting annual costs by outpatient reimbursements was 5.5% lower for 5-day PR platelets as compared to 5-day LVDS (US$1.663 vs. US$1.760M). A mix of 7-day LVDS and 5-day PR platelets had net annual costs that were 1.3% lower than for 100% 7-day LVDS, but 1.3% higher than for 100% 5-day PR. 7-day PR platelets had the longest shelf life (4.63 days), while 5-day LVDS had the shortest (2.00 days). DISCUSSION: The model identifies opportunities to minimize transfusion center costs for 5- and 7-day platelets. Budget impact models such as this are important for understanding the financial implications of evolving FDA guidance and new platelet technologies.


Assuntos
Plaquetas , Transfusão de Plaquetas , Plaquetas/microbiologia , Transfusão de Sangue , Custos e Análise de Custo , Humanos , Transfusão de Plaquetas/métodos , Manejo de Espécimes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...